Hi All, I have a routine for 24c02 which works very well. Now on the same PCB I mounted a 24c64 in place of 24c02 EEPROM. The old Read/Write routine didn't work on this. I am unable to find what could be the possible problem. What are the changes which have to be made when migrating a code from 24c02 EEPROM to 24c64 EEPROM. Thanks in advance, Rohan

24C02 and 24C64
Started by ●April 23, 2007
Reply by ●April 23, 20072007-04-23
Rohan wrote:> Hi All, > > I have a routine for 24c02 which works very well. Now on the same PCB > I mounted a 24c64 in place of 24c02 EEPROM. The old Read/Write routine > didn't work on this. > > I am unable to find what could be the possible problem. What are the > changes which have to be made when migrating a code from 24c02 EEPROM > to 24c64 EEPROM.You _did_ try reading and comparing the data sheets ? As a hint, look at the data sheets, and search for Page and address, and compare them. -jg
Reply by ●April 23, 20072007-04-23
On Apr 23, 1:23 pm, Jim Granville <no.s...@designtools.maps.co.nz> wrote:> Rohan wrote: > > Hi All, > > > I have a routine for 24c02 which works very well. Now on the same PCB > > I mounted a 24c64 in place of 24c02 EEPROM. The old Read/Write routine > > didn't work on this. > > > I am unable to find what could be the possible problem. What are the > > changes which have to be made when migrating a code from 24c02 EEPROM > > to 24c64 EEPROM. > > You _did_ try reading and comparing the data sheets ? > As a hint, look at the data sheets, and search for Page and address, > and compare them. > > -jgThanks Jim, Found the problem. The address is 16 bit format and there is an acknowledge bit in between. I was missing the acknowledge. Thanks for your help, Rohan