Accelerometer | ADC | ADXL | Adxl20 | AVR | BasicStamp | BX-35 | BX28 | BX35 | COM3 | Compiler | Downloader | EEPROM | Electromagnet | GetADC | GP2D1 | GPS | I2C | IDE | Keypad | LCD | LCD+ | MIDI | Motors | Multitasking | Netmedia | Networking | PCB | PID | PlaySound | PWM | Relays | RTC | Servo | ShiftOut | SitePlayer | SPI | Stack | Timer | USB

Ads

Discussion Groups

See Also

DSPFPGAElectronics

Discussion Groups | BasicX | Re: Digest Number 1762

Discussion forum for the BasicX family of microcontroller chips.

Re: Digest Number 1762 - andrew meehan - Sep 7 0:29:00 2004

hi, i hope this helps. changing the duty cycle
changes the length of time a pulse is pos. or neg. ,
but NOT the speed of the frequency or in your case
the number of readings a second. try to change the
frequency to a higher amount. this is what i know
about duty cycles but i haven't worked with the
ADXL202, keep this in mind.

> Message: 1
> Date: Mon, 06 Sep 2004 16:22:13 -0000
> From: "larzyharzy" <>
> Subject: adxl202 - improving reading rate
>
> I am experimenting with an ADXL202.
>
> I have been testing it with the two example programs
> DisplayAngle and
> DisplayAcceleration.
>
> My problem is that I only get 5 - 6 readings a
> second.
>
> I have tried changing the resistor that controls the
> duty cycle for the accelerometer.
> The lowest value I have tried is 125k ohm, which
> should set the duty cycly to 1 ms
> according to the datasheet for the ADXL202.
>
> Why do I only get so few readings a second? Is it
> because of the calculations the BX24
> has to perform?
>
> /lars __________________________________




______________________________
controlSUITE™ software. Comprehensive. Intuitive. Optimized.
Real-world software for real-time control. Details Here!



(You need to be a member of basicx -- send a blank email to basicx-subscribe@yahoogroups.com )


Re: Digest Number 1762 - andrew meehan - Sep 7 15:08:00 2004

hi, i hope this helps. changing the duty cycle
changes the length of time a pulse is pos. or neg. ,
but NOT the speed of the frequency or in your case
the number of readings a second. try to change the
frequency to a higher amount. this is what i know
about duty cycles but i haven't worked with the
ADXL202, keep this in mind.

> Message: 1
> Date: Mon, 06 Sep 2004 16:22:13 -0000
> From: "larzyharzy" <>
> Subject: adxl202 - improving reading rate
>
> I am experimenting with an ADXL202.
>
> I have been testing it with the two example programs
> DisplayAngle and
> DisplayAcceleration.
>
> My problem is that I only get 5 - 6 readings a
> second.
>
> I have tried changing the resistor that controls the
> duty cycle for the accelerometer.
> The lowest value I have tried is 125k ohm, which
> should set the duty cycly to 1 ms
> according to the datasheet for the ADXL202.
>
> Why do I only get so few readings a second? Is it
> because of the calculations the BX24
> has to perform?
>
> /lars __________________________________